For the control of e.g. stamping residues undesired simultaneous intake of two metal sheets, and rupture of springs
- Connection with up to four analog sensors (0 - 10 VDC)
- 4 inputs control 1 output, i.e. one tool controller occupies only
- 1 input, signal pre-processing with µ controller, PNP output for subsequent tool control!
- Modification of existing tool control systems
- Easy setting of distance by means of optical signal display and AUTOSET
- Menu management via 4 keys and display
- Cycle by cycle control (actual value/rated value follow-up in every cycle)
- Setting/changing of accuracy via keys
- No start of the press when the sensor settings are not correct
- High controlling accuracy
- Menu guide in German and English
|